CFE

These mounts offer a low profile, easy to install design with an integral fail-safe device to provide shock and failure protection for mobile, marine or seismic stationary application and for applications where safety is paramount. When the rubber works in shear and compression it provides large static deflections, low natural frequency (to 8 Hz) and high isolation. Our CFE range can accommodate loads between 7.5 kg to 83 kg per mount.

TECHNICAL FEATURES

Item Hardness
(IRHD)
A B P FxM CF L S Average
stiffness
(Kg/mm)
Max.
load
(Kg)
Max.
deflection
(mm)
CFE623110XW 35 60 31 M10 8,3X16 75-90 106 3 7,5 25 3,3
CFE623110W 45 60 31 M10 8,3X16 75-90 106 3 10,0 34 3,4
CFE623110K 50 60 31 M10 8,3X16 75-90 106 3 13,0 43 3,3
CFE623110M 60 60 31 M10 8,3X16 75-90 106 3 16,0 53 3,3
CFE623110H 70 60 31 M10 8,3X16 75-90 106 3 25,0 83 3,3
CFE623112W 45 60 31 M12 8,3X16 75-90 106 3 10,0 34 3,4
CFE623112K 50 60 31 M12 8,3X16 75-90 106 3 13,0 43 3,3
CFE623112M 60 60 31 M12 8,3X16 75-90 106 3 16,0 53 3,3
CFE623112H 70 60 31 M12 8,3X16 75-90 106 3 25,0 83 3,3

 

FIBET bell mounts can withstand up to 2g of shock forces or 5g occasional shock forces, with regards to the load, without permanent deformation or failing.

 

APPLICATIONS
Gensets, marine power engines, diesel engines, pumps, HVAC

STANDARD PRODUCTION
Bell and Flange: DD13 or DC04 steel (UNI EN 10111 or UNI EN 10130)
Fail-safe device: 11SMnPb37 (UNI EN 10087)
Natural rubber NR
Zinc plated in accordance with CE standards, CHROME VI free, white
Stiffness tolerance: ± 20%

OPTIONS AND ADDITIONAL PARTS
Stainless steel version