CFBMS_type1

Mounts which allow a high level of insulation, especially used on generators, engines and systems with an operating frequency at around 25 Hz (1500 rpm). The CFBMS are designed with a fail-safe function making them an ideal solution for applications where safety is paramount. Axial stresses are perfectly absorbed and side deflections limited to guarantee a good stability. The “Type 1” range can accommodate loads between 7 kg to 800 kg per mount.

TECHNICAL FEATURES

Item Hardness
(IRHD)
A B P FxM CF L S Average
stiffness
(Kg/mm)
Max.
load
(Kg)
Max.
deflection
(mm)
CFBMS633510M 60 63 35 M10 9X14 89 110 2.5 15,8 60 3,8
CFBMS633610W 45 63 36 M10 15X11 100 120 2,5 14 60 4,3
CFBMS633610M 60 63 36 M10 15X11 100 120 2,5 31,5 120 3,8
CFBMS833510W 40 83 35 M10 11,5X15 110 135 3 17,8 80 4,5
CFBMS833510M 60 83 35 M10 11,5X15 110 135 3 44,5 180 4
CFBMS833512W 40 83 35 M12 11,5X15 110 135 3 17,8 80 4,5
CFBMS833512M 60 83 35 M12 11,5X15 110 135 3 44,5 180 4
CFBMS1064212W 40 106 42 M12 14X18 143 175 4 33,5 167 5
CFBMS1064212M 60 106 42 M12 14X18 143 175 4 67 335 5
CFBMS1064216W 40 106 42 M16 14X18 143 175 4 33,5 167 5
CFBMS1064216M 60 106 42 M16 14X18 143 175 4 67 335 5
CFBMS1505416W 40 150 54 M16 14X18 182 216 4 37,5 450 12
CFBMS1505416M 60 150 54 M16 14X18 182 216 4 78,7 800 10,2

 

FIBET bell mounts can withstand up to 2g of shock forces or 5g occasional shock forces, with regards to the load, without permanent deformation or failing.

 

APPLICATIONS
Gensets, engines, special equipments, tooling equipments, pumps, HVAC

STANDARD PRODUCTION
Bell and Flange: DD13 or DC04 steel (UNI EN 10111 or UNI EN 10130)
Fail-safe device: 11SMnPb37 (UNI EN 10087)
Natural rubber NR
Zinc plated in accordance with CE standards, CHROME VI free, white
Stiffness tolerance: ± 20%

OPTIONS AND ADDITIONAL PARTS
Stainless steel version
Height adjuster